What a specification's glass type and glass layers mean, how glass surfaces are numbered, and what each glass setting does.

Who can do this: Anyone who can open the project. Field/shop workers can open only the projects they are scheduled for in the calendar.

A specification's Glass layers describe the glass makeup for its openings: each piece of glass and what sits between the pieces. You set them when you add or edit a specification. See Add specifications and elevations.

The glass layers:

  • Show on the Product submission data page of the online proposal (see Send a proposal). The page shows the glass type as Typical glass type and each layer's settings under Glass layers, leaving out blank settings. The Summary page shows only Typical glass type.
  • Set the glass color in the elevation drawings (see Glass color in drawings).

They don't change the price, the glass sizes, the glass lists, vendor quotes or orders.

Glass types

The glass type comes from the product system you pick for the specification. You can't change it in the proposal. It sets which layers you see.

The Add specification and Edit specification windows don't show the glass type's name, but you can tell it from the layer headings (see How glass surfaces are numbered). If the product system has no glass type, the Add specification window has no Glass layers section, and the Edit specification window says "This system has no glass type."

Glass typeWhat it isLayers, from the outside in
MonolithicA single piece of glass.One glass layer
LaminatedTwo pieces of glass bonded face to face by a plastic interlayer.Glass, interlayer, glass
InsulatedTwo pieces of glass sealed around their edges with a spacer, with an air space between them.Glass, air space, glass
Insulated-LaminatedAn insulated unit whose inner glass is laminated.Glass, air space, glass, interlayer, glass
Laminated-InsulatedAn insulated unit whose outer glass is laminated.Glass, interlayer, glass, air space, glass

Glass layers always alternate with an interlayer or an air space. Two pieces of glass are never next to each other.

How glass surfaces are numbered

Each layer's heading names the glass surfaces it covers, so it helps to know how surfaces are numbered:

  • Surface 1 is the outside face of the outermost piece of glass.
  • Each piece of glass has two surfaces. The first piece has surfaces 1 and 2, the second has 3 and 4, and the third has 5 and 6.
  • Odd-numbered surfaces face the outside. Even-numbered surfaces face the inside.

So a glass layer is headed Surface 1 & 2, Surface 3 & 4 or Surface 5 & 6. An interlayer or air space is headed by the two surfaces it sits between, such as Surface 2-3 or Surface 4-5.

For an Insulated glass type, the layers are:

HeadingWhat it is
Surface 1 & 2The outer piece of glass. Surface 1 faces the outside.
Surface 2-3The air space between the two pieces.
Surface 3 & 4The inner piece of glass. Surface 4 faces the room.

Glass settings

Each layer has a dropdown for each setting. When you add a specification, each setting starts at its default. Odd Surface and Even Surface start blank. The defaults show on the Product submission data page just like settings you pick, so check each one against the plans.

Glass layer

SettingWhat it sets
Glass ThicknessThe thickness of this piece, such as 1/4" (the default) or 3/8".
ColorThe glass color: Clear (the default), Bronze, Gray, Low-Iron, Light Green or Light Blue. Pick Custom Color for any other color. BidUnity doesn't record which custom color you mean.
Heat TreatmentTempered (the default), Heat Strengthened or Annealed.
Odd SurfaceA coating or texture on this piece's outside face (surface 1, 3 or 5), such as Low-E (a thin coating that cuts the heat passing through the glass), Ceramic Frit or Reflective.
Even SurfaceA coating or texture on this piece's inside face (surface 2, 4 or 6), such as Low-E, Ceramic Frit or Back-Painted.

In the Add specification window, a blank Odd Surface or Even Surface box reads "No options". That means no coating is picked. In the Edit specification window, a blank box shows "—". Once you pick a coating, you can change it to another coating, but you can't set the surface back to blank.

Interlayer

SettingWhat it sets
Interlayer MaterialThe interlayer material, such as PVB (the default) or SGP.
Interlayer ThicknessThe interlayer thickness in inches, such as 0.090 (the default) or 0.060.
Interlayer ColorClear (the default), White or Custom.

Air space

SettingWhat it sets
Air Spacer TypeThe material and color of the spacer around the edge of the unit: Aluminum (the default), Bronze Aluminum or Thermal (SuperSpacer).
Gas Fill TypeThe gas in the air space: Air (the default) or Argon.
GridNo Grid (the default) or Colonial Grid.

There is no setting for the width of the air space or the overall thickness of the unit.

Example: enter an insulated makeup

Say the plans call for an insulated unit with 1/4" clear tempered glass outside with a Low-E coating on surface 2, an argon-filled air space, and 1/4" clear tempered glass inside. On a specification whose layers are Surface 1 & 2, Surface 2-3 and Surface 3 & 4 (the Insulated glass type):

  1. Under Surface 1 & 2, check that Glass Thickness is 1/4", Color is Clear and Heat Treatment is Tempered. Set Even Surface to Low-E.
  2. Under Surface 2-3, set Gas Fill Type to Argon.
  3. Under Surface 3 & 4, check that Glass Thickness is 1/4", Color is Clear and Heat Treatment is Tempered.

A Low-E coating on surface 3 would go under Surface 3 & 4, in Odd Surface.

In a Laminated-Insulated unit, surfaces 2 and 3 face the interlayer and surface 4 faces the air space. A coating on surface 4 goes under Surface 3 & 4, in Even Surface.

Change the glass settings

You can change the glass settings until the proposal is finalized, and only while the project is open.

  1. Click Edit in the specification's heading.
  2. Click Glass layers to open them.
  3. Change the settings you need.
  4. Click Save changes.

Changing only the glass settings doesn't rebuild pricing. The list of changes at the bottom of the window shows them as Glass, with the number of settings you changed.

Glass color in drawings

The elevation editor and the saved elevation drawings show the glass in one color, taken from the glass layers:

  • BidUnity looks at the glass layers from the outside in and uses the first tinted color it finds: Bronze, Gray, Light Green or Light Blue.
  • If the first tinted glass is Custom Color, the glass draws as clear, even when glass further in is tinted.
  • If no glass is tinted, the glass draws as Low-Iron when the outer glass is Low-Iron, and as clear otherwise.

The interlayer color doesn't change the drawings. When you change a glass layer's Color, BidUnity redraws the specification's saved elevation drawings.